Difference between revisions of "Rebus"
From CHG-Wiki
Jump to navigationJump to searchm |
(Noted replaced 2TB drives in rebus RAID.) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
{| class="wikitable" | {| class="wikitable" | ||
! System Name: | ! System Name: | ||
− | |align="right"|rebus. | + | |align="right"|rebus.chg.ucsb.edu |
|- | |- | ||
! IP: | ! IP: | ||
− | |align="right"|128.111.78.48 | + | |align="right"|<em>(need info)</em> (ERI subnet) <!-- used to be 128.111.78.48--> |
|- | |- | ||
! IPMI IP: | ! IPMI IP: | ||
− | |align="right"|128.111.73.52 | + | |align="right"|<em>(need info)</em> (ERI subnet) <!-- used to be 128.111.73.52--> |
|- | |- | ||
! Location: | ! Location: | ||
Line 60: | Line 60: | ||
==Services== | ==Services== | ||
CHG backup server. | CHG backup server. | ||
+ | |||
+ | ==Notes== | ||
+ | *Rebus was moved from Bren 4026 to the ERI sixth floor server room on June 21st, 2016. Will soon be moved to North Hall Data Center. | ||
+ | *Network bridge configured and enabled. | ||
+ | */eri mount hung when restarting network (06/22/2016). | ||
+ | *ERI replaced two 2TB drives that had failed on rebus with spares they had on hand (August 2017). | ||
==VMs== | ==VMs== |
Latest revision as of 09:42, 14 September 2017
Rebus is the CHG backup server.
General Info
System Name: | rebus.chg.ucsb.edu |
---|---|
IP: | (need info) (ERI subnet) |
IPMI IP: | (need info) (ERI subnet) |
Location: | Bren 4026(Bren Server Room) |
UCID #: | 108000408 |
Grant #: | (need info) |
Serial #: | AH1000438 |
General Purpose: | Backup Server |
Purchase Date: | (need info) |
Delivery Date: | (need info) |
Vendor: | (need info) |
Contract #: | (need info) |
Support Expires: | (need info) |
System Configuration
- OS Type: CentOS
- OS Version: CentOS 6.7
- CPU info: 8xIntel Xeon 2.06GHz
- Chassis Specs: 8xdrive bays, (4U), (more info needed)
Network
- NIC speed: Gigabit
- MAC Address - eth0: 00:25:90:1d:04:e0
- MAC Address - eth1: (need info)
Storage
- Memory: 12GB (DDR3?)
- HD: 16TB, RAID6
Services
CHG backup server.
Notes
- Rebus was moved from Bren 4026 to the ERI sixth floor server room on June 21st, 2016. Will soon be moved to North Hall Data Center.
- Network bridge configured and enabled.
- /eri mount hung when restarting network (06/22/2016).
- ERI replaced two 2TB drives that had failed on rebus with spares they had on hand (August 2017).
VMs
System Name: | IP: | Notes: |
---|---|---|
chg-dev | 128.111.73.58 | Development box for chg website. |